undergraduate thesis
Potenciometrijska titracija kationskih tenzida i etoksiliranih neionskih tenzida

Mateja Hajduković (2010)
Sveučilište Josipa Jurja Strossmayera u Osijeku
Odjel za kemiju
Metadata
TitlePotenciometrijska titracija kationskih tenzida i etoksiliranih neionskih tenzida
AuthorMateja Hajduković
Mentor(s)Milan Sak-Bosnar (thesis advisor)
Abstract
Za određivanje kationskih i neionskih tenzida potenciometrijskom titracijom korišten je osjetljivi tenzidni senzor baziran na 1,3-didecil-2-metil-imidazolijevom kationu i tetrafenilboratnom (TPB) antagonist-ionu kao detektoru završne točke pri potenciometrijskoj titraciji. Natrijev tetrafenilborat upotrebljen je kao titrant. Potenciometrijskom metodom titrirano je nekoliko kationskih (CS) i etoksiliranih neionskih tenzida (EONS), analitičke i tehničke čistoće, pojedinačno i u smjesi. Senzor je pokazao zadovoljavajuće rezultate u rasponu pH 3-10, te zadovoljavajuću selektivnost za sve ispitivane kationske i neionske tenzide. Ionska jakost nije bitno utjecala na titraciju, osim pri koncetraciji 0,1 M NaCl, gdje je došlo do manjeg izobličenja druge točke infleksije koja odgovara titraciji neionskog tenzida. Različite kombinacije dvokomponentnih smjesa četiri kationska i tri etoksilirana neionska tenzida titrirane su potenciometrijski koristeći ranije navedeni senzor kao detektor završne točke. Količine ispitivanih tenzida varirale su između 2 i 6 µmolova za kationski tenzid te 2,50 i 7,50 µmolova za etoksilirani neionski tenzid. Veće pogreške javljale su se ako je odnos utrošaka titranta za svaku komponentu u smjesi premašilo vrijednost 3:1. Pogreške se mogu značajno smanjiti izvođenjem preliminarne titracije i naknadnim dodatkom poznate količine tenzida prisutnog u nižoj koncentraciji.
Keywordssurfactant sensor PVC membrane cationic surfactant ethoxylated nonionic surfactant potentiometric titration
GranterSveučilište Josipa Jurja Strossmayera u Osijeku
Odjel za kemiju
PlaceOsijek
StateCroatia
Scientific field, discipline, subdisciplineNATURAL SCIENCES
Chemistry
Study programme typeuniversity
Study levelundergraduate
Study programmeChemistry
Academic title abbreviationuniv. bacc. chem.
Genreundergraduate thesis
Language Croatian
Defense date2010
Parallel abstract (English)
A sensitive potentiometric surfactant sensor based on a highly lipophilic 1,3-didecyl-2-methyl-imidazolium cation and a tetraphenylborate antagonist ion has been used as the endpoint detector in ion-pair surfactant potentiometric titrations using sodium tetraphenylborate as titrant. Several analytical and technical grade cationic (CS) and ethoxylated nonionic surfactants (EONS), single and the mixtures of both were potentiometrically titrated. The sensor showed satisfactory analytical performances within a pH range of three to ten, and exhibited satisfactory selectivity for both, CS and EONS investigated. The ionic strength didn’t influence the titration except at 0.1 M NaCl, where a slight distortion of the second inflexion related to the nonionic surfactant was evidenced. Any two-component combination of four CS and three EONS has been potentiometrically titrated using the sensor mentioned as the end-point detector. The quantities of the surfactants investigated varied between 2 and 6 µmols for CS and 2,50 and 7,50 µmols for EONS. The larger errors appeared if the ratio of titrant consumptions for each component in the mixture exceeds the value of 3:1 can be significantly reduced by performing a preliminary titration and a subsequent known addition of the surfactant present at lower concentration.
Parallel keywords (Croatian)potenciometrijska titracija kationski tenzidi neionski tenzidi PVC membrana senzor
Resource typetext
Access conditionOpen access
Terms of usehttp://rightsstatements.org/vocab/InC/1.0/
URN:NBNhttps://urn.nsk.hr/urn:nbn:hr:182:950242
CommitterSanda Hasenay