master's thesis
Lightning protection standards and system in buildings

Hinko Horvatić (2015)
Metadata
TitleRegulativa i sustav zaštite od djelovanja munja na građevine
AuthorHinko Horvatić
Mentor(s)Predrag Marić (thesis advisor)
Abstract
Diplomski rad opisuje sustavu zaštite od udara munje u građevine koje su nakon toga primijenjene za ispitivanu građevinu u Belom Manastiru. Ispitivanje se vršilo u obliku vizualnog i mjernog ispitivanja. Izvršeni pregledi i mjerenja su bila u granicama s normom HRN EN 62305 te je ta građevina zadovoljila sve standarde u sustavu zaštite od udara munje. Da bi sustav bio potpun obavila se simulacija udara munje u DIgSILENT PowerFactory sučelju gdje je pokazano na koji način se ponaša distributivna mreža u slučaju udara munje.
Keywordslightning strike HRN EN 62305 DIgSILENT
Parallel title (English)Lightning protection standards and system in buildings
Committee MembersPredrag Marić (committee chairperson)
Tomislav Barić (committee member)
Krešimir Miklošević (committee member)
GranterSveučilište Josipa Jurja Strossmayera u Osijeku
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek
Lower level organizational unitsZavod za elektroenergetiku
Katedra za elektroenergetske mreže i postrojenja
PlaceOsijek
StateCroatia
Scientific field, discipline, subdisciplineTECHNICAL SCIENCES
Electrical Engineering
Power Engineering
Study programme typeuniversity
Study levelgraduate
Study programmeGraduate University Study Programme in Electrical Engineering; specializations in: Communications and Informatics, Power Engineering
Study specializationPower Engineering
Academic title abbreviationmag.ing.el.
Genremaster's thesis
Language Croatian
Defense date2015-07-15
Parallel abstract (English)
This diploma paper discusses in the system of protection against lightning strike into a building. Those regulations were applied on the tested building in Beli Manastir. The testing was done visually and by measuring. Performed testing and measurements were in the limits of the norm HRN EN 62305 so that building satisfied all standards within the system of protection against lightning strike. To make the system complete, lightning strike simulation was performed in the DigSILENT Power Factory software where it was shown how distributive network responsed in the case of lightning strike.