master's thesis
Analysis of transient overvoltage on HV SF6 switchgear plants of compact performance

Dino Horvat (2015)
Sveučilište Josipa Jurja Strossmayera u Osijeku
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek
Zavod za elektroenergetiku
Katedra za elektroenergetske mreže i postrojenja
Metadata
TitleAnaliza tranzientnih prenapona na VN SF6 sklopnim postrojenjima kompaktne izvedbe
AuthorDino Horvat
Mentor(s)Zoran Baus (thesis advisor)
Marinko Barukčić (thesis advisor)
Abstract
U ovom diplomskom radu opisano je GIS postrojenje, kroz povijesni razvoj, kao i izolacijski medij SF6. U poglavlju 3, opisane su prijelazne pojave, kao i kvarovi uzrokovani prijelaznim pojavama. U poglavlju 4. GIS postrojenje modelirano je u programskom paketu ATP. Simulacijom dobiveni valni oblici prijelaznih prenapona, također su prikazani u poglavlju 4.
KeywordsGas Insulated Substations GIS SF6 transients overvoltages simulation ATP
Parallel title (English)Analysis of transient overvoltage on HV SF6 switchgear plants of compact performance
Committee MembersZoran Baus (committee chairperson)
Goran Knežević (committee member)
Marinko Barukčić (committee member)
GranterSveučilište Josipa Jurja Strossmayera u Osijeku
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek
Lower level organizational unitsZavod za elektroenergetiku
Katedra za elektroenergetske mreže i postrojenja
PlaceOsijek
StateCroatia
Scientific field, discipline, subdisciplineTECHNICAL SCIENCES
Electrical Engineering
Power Engineering
Study programme typeuniversity
Study levelgraduate
Study programmeGraduate University Study Programme in Electrical Engineering; branch: Communications and Informatics, Power Engineering
Study specializationPower Engineering
Academic title abbreviationmag.ing.el.
Genremaster's thesis
Language Croatian
Defense date2015-10-01
Parallel abstract (English)
In this graduate work are described historical development of Gas Insulated Substations, and insulation medium SF6. Transients and faults caused by them are described in Chapter 3. In Chapter 4, GIS is modeled in ATP computer program. By simulating the resulting waveforms of transient overvoltages, graphs are presented in Chaper 4.
Parallel keywords (Croatian)plinom izolirano viskokonaponsko postrojenje GIS SF6 prijelazne pojave prenaponi simulacija ATP
Resource typetext
Access conditionOpen access
Terms of usehttp://rightsstatements.org/vocab/InC/1.0/
URN:NBNhttps://urn.nsk.hr/urn:nbn:hr:200:502610
CommitterAnka Ovničević