master's thesis
Digital tranciever for the intra body communications based on the wideband signal

Zvonimir Golubović (2015)
Metadata
TitleDigitalni primopredajnik za komunikaciju putem ljudskog tijela zasnovan na širokopojasnom signalu
AuthorZvonimir Golubović
Mentor(s)Marijan Herceg (thesis advisor)
Abstract
U ovom radu opisan je sustav za prijenos putem tijela. Korištenjem ljudskog tijela kao medija za prijenos podataka omogućuje se široki spektar potencijalnih primjena od zdravstvenog nadzora do osobne zabave. Teorija kapacitivne sprege zasnovana je na temelju kapacitivne veze ljudskog tijela prema njegovoj okolini. Frekvencijski opseg od 10 kHz do 100 MHz najpogodniji je za prijenos širokopojasnog signala putem ljudskog tijela. Opisana je izvedba sklopa. U okviru rada napravljeni su predajnik i prijemnik na prototipnoj pločici. Jedan od ciljeva rada bio je prenijeti podatak putem ljudskog tijela te prikazati mjerne rezultate.
Keywordshuman body capacitive coupling data transfer
Parallel title (English)Digital tranciever for the intra body communications based on the wideband signal
Committee MembersMarijan Herceg (committee chairperson)
Tomislav Matić (committee member)
Mario Vranješ (committee member)
GranterSveučilište Josipa Jurja Strossmayera u Osijeku
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek
Lower level organizational unitsZavod za komunikacije
Katedra za elektroniku i mikroelektroniku
PlaceOsijek
StateCroatia
Scientific field, discipline, subdisciplineTECHNICAL SCIENCES
Electrical Engineering
Electronics
Study programme typeuniversity
Study levelgraduate
Study programmeGraduate University Study Programme in Electrical Engineering; branch: Communications and Informatics, Power Engineering
Study specializationbranch: Communications and Informatics
Academic title abbreviationmag.ing.el.
Genremaster's thesis
Language Croatian
Defense date2015-12-22
Parallel abstract (English)
This paper describes a body transmission system. Using a human body as a medium for data transfer provides a wide range of potential applications, from health management to personal entertainment. The theory of capacitive coupling is established based on the capacitive coupling of the human body to its surrounding environment. A frequency range of 10 kHz to 100 MHz is the most suitable for the wideband signaling over human body. Assembly performance is described. A part of this paper, transmitter and receiver were made on a prototype board. One of the aims of this paper was to transmit data over the human body and to represent the results of measurement.
Parallel keywords (Croatian)ljudsko tijelo kapacitivna sprega prijenos podataka
Resource typetext
Access conditionOpen access
Terms of usehttp://rightsstatements.org/vocab/InC/1.0/
URN:NBNhttps://urn.nsk.hr/urn:nbn:hr:200:213947
CommitterAnka Ovničević