master's thesis
Relaibility analysis of transmission network PrP Osijek with influence of possible new generators

Anto Topić (2016)
Metadata
TitleAnaliza pouzdanosti mreže PrP Osijek sa utjecajem mogućih novih izvora
AuthorAnto Topić
Mentor(s)Srete Nikolovski (thesis advisor)
Abstract
U radu se analizira utjecaj planiranih velikih kombiniranih kogeneracijskih elektrana KKE Ernestinovo i KKE Brod koje se priključuju na 110 kV mrežu u Ernestinovu i Slavonskom brodu, kao i tri male KKE koje se priključuju na 110 kV mrežu u Slavonskom Brodu, Vinkovcima i Vukovaru, na pokazatelje pouzdanosti prijenosne mreže prijenosnog područja Osijek. U radu je korišten model prijenosne mreže istočne Hrvatske u programskom paketu DIgSILENT. Također je uzet u obzir prekogranični prijenos snage kao i dnevna maksimalna/minimalna opterećenja 110 kV stanica u prijenosnoj mreži. Na kraju su uspoređeni rezultati za pojedine slučajeve.
KeywordsPrP Osijek new source
Parallel title (English)Relaibility analysis of transmission network PrP Osijek with influence of possible new generators
Committee MembersSrete Nikolovski (committee chairperson)
Predrag Marić (committee member)
Marko Vukobratović (committee member)
GranterSveučilište Josipa Jurja Strossmayera u Osijeku
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek
Lower level organizational unitsZavod za elektroenergetiku
Katedra za elektroenergetske mreže i postrojenja
PlaceOsijek
StateCroatia
Scientific field, discipline, subdisciplineTECHNICAL SCIENCES
Electrical Engineering
Power Engineering
Study programme typeuniversity
Study levelgraduate
Study programmeGraduate University Study Programme in Electrical Engineering; specializations in: Communications and Informatics, Power Engineering
Study specializationPower Engineering
Academic title abbreviationmag.ing.el.
Genremaster's thesis
Language Croatian
Defense date2016-10-05
Parallel abstract (English)
The paper analyzes the impact of the planned two big combine cycle cogeneration power plants (CCCPP) Ernestinovo and Brod which are connects on the 110 kV network grid in Ernestinovo and Slavonski Brod, on the transmission network indicators of reliability of the eastern croatian transmission network . Also, paper analyzes the impact of the three small planned plants which are connects on the 110 kV network grid in Slavonski Brod, Vinkovci and Vukovar, on the same indicators. In this paper we used the model of transmission network in the eastern Croatia in software package DIgSILENT. The analysis takes into account the cross – border transfer of power as well as daily maximum/minimum load of 110 kV stations in the transmission network. In the end, comparison of results for certain cases was made.
Parallel keywords (Croatian)PrP Osijek novi izvori
Resource typetext
Access conditionOpen access
Terms of useAll rights reserved
URN:NBNhttps://urn.nsk.hr/urn:nbn:hr:200:565339
CommitterAnka Ovničević